<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-16 02-29-49
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.90 MHz 5/5, 34 dBuV PROGLAS,
Pilot RDS Phase Difference
6.5 kHz 3.9 kHz -2 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
11 kHz 56 kHz 18464 0,0433
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,4 dBr -0,88 dBr -0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"PROGLAS," 2AA1 7 (Culture) 0 0 1 1 --:--
RT
"KRESTANSKA ROZHLASOVA STANICE "
AF EON
88.7, 89.5, 92.3, 93.3, 96.0, 96.4, 97.9, 99.0, 100.6, 104.0, 107.5 MHz -
FM Scope Max at: 56 kHz MIN: 11 kHz % above 77 kHz: 0,0433 Acquired: 2024/01/16 2:29:46 Total samples: 18464 Equivalent time: 0:15:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,2 dBr MIN: -2,4 dBr AVE: -0,88 dBr % above 0,2 dBr: 0,0 Last value: -0,4 dBr (2024/01/16 2:29:46) 02:16 02:18 02:20 02:22 02:24 02:26 02:28 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality